steam boiler Agent drop header


The importance of near-boiler piping in a steam system

The drop header(s) piping is sized to match the two top tappings in the steam chest which lets the boiler make more dry steam at a faster rate through the twin steam chest tappings and also making the boiler more efficient in the process in making dry steam using a common condensate drain from the drop headers back to the boilers water level. The drop headers also allow the dry steam to be fed faster …

Free Chat

Section 23 52 39 - FIRE-TUBE BOILERS

At Maximum Required Output: On each fuel at site altitude, with and without economizer (if applicable) in service, at 15 percent excess air. Data must include fuel and steam flow, boiler flue gas outlet temperature, economizer (if provided) flue gas outlet temperature, steam quality, boiler efficiency, furnace pressures, and predicted boiler radiation and unaccounted losses, feedwater and flue

Free Chat

U.S.C.G. Merchant Marine Exam Third Assistant Engineer

The main steam stop bypass valve is used to _____. o (A) supply auxiliary steam when the main steam stop is closed o (B) cross-connect two steaming boilers o (C) isolate the main steam stop for repairs while steaming • (D) gradually increase the pressure and temperature of the main steam …

Free Chat

3. STEAM SYSTEM - Bureau of Energy Efficiency

As steam condenses in a process, flow is induced in the supply pipe. Condensate has a very small volume compared to the steam, and this causes a pressure drop, which causes the steam to flow through the pipes. The steam generated in the boiler must be conveyed through pipework to the point where its heat energy is required.

Free Chat

Recent Experience in Condition Assessment of Boiler Header

stub to header welds. Steam piping flexibility can cause excessive loads to be transmitted to a header outlet nozzle. The subject of the interactions between steam piping and boiler headers is presented in detail in the Reference 2 paper. The low temperature headers are …

Free Chat

IME Quiz 2 Main Steam System Flashcards | Quizlet

Auxiliary boilers provide saturated steam at a lower pressure. Supplied at full and reduced pressures. Saturated steam comes from desuperheater on main propulsion boiler. Gland seal systems. Supplied at ½ to 2 psig for sealing glands to prevent air leakage into condenser and prevent leakage out of …

Free Chat

Engineering Branch Training - Part 2 - HNSA

Steam should never be raised too quickly in any boiler. In Scotch boilers this tends to distort the entire boiler shell, causing ruptures of the tubes, furnaces, or the shell itself. In watertube boilers, raising steam too quickly is not injurious to the boiler itself, but the rapid …

Free Chat

ALL YOUVE EVER NEEDED TO KNOW ABOUT STEAM BUT …

this header is first reduced in pressure to 10 psi and then cooled down with water injection as close as possible to the saturation temperature for 10 psi steam of 240°F. Your lumber quality will improve immensely, your boiler will be loafing, your fuel bill will drop dramatically. As I said at the beginning, steam is an amazing substance.

Free Chat

Weil Mclain SGO-8 Gas Fired Steam Boiler With A Mega Drop

Jun 24, 2014 · I think the bottom of the steam header should be a minimum of 24 inches above the top of the boiler jacket, and more than that, if possible. The higher the header, the drier the steam will be. Pros who do steam know this. Many of them use a Dead Man trick called a drop header.

Free Chat

Heat Tracing In Piping: Types, Working, Use, Installation

Apr 13, 2021 · Latent heat of steam is soaked by process pipe through radiant heat transfer and condensate is collected with help of Steam trap. In few words, Steam from a boiler to the steam header and finally to steam tracer through steam manifold losses its latent heat to process pipe via radiant heat transfer. This is how does steam heat tracing works.

Free Chat

LGB - Weil-McLain

(Except for all IRI boilers and LGB™-21 through 23 boilers with CSD-1/FM.) All LGB™-6 through 23 boilers (except for all IRI and LGB-21) are capable of low-high-low or staged firing with an additional operating limit control. Factory-assembled base and burners reduce installation time. Simplified piping. The largest LGB™ steam boiler

Free Chat

Multiple pass economizer and method for SCR temperature

For a general description of such types of boilers or steam generators, For example, when the controller 9 detects a drop in the boiler load or in the gas temperature at the economizer flue inlet or outlet, the flow of feedwater through each tubular configuration is adjusted to reduce the combined heat transfer capacity of the economizer

Free Chat

Steam System Design and Best Practices Related to Kiln Drying

Steam Boiler – high or low pressure Typical Steam Distribution Header. New England Kiln Drying Association – Steam Design & Best Practices – HerLine Technologies Pipe Sizing drop …

Free Chat

Tips for a Successful Steam Boiler Replacement | U.S

Jun 14, 2018 · Other than the boiler header, you should never pipe a steam riser into the bull (side outlet) of a tee. See Figure 1. Figure 1. A dropped header produces dryer steam. Although a dropped header is not a requirement, dryer steam moves faster, stays in a steam state longer, and has less of a chance for system noise caused by excessive water in

Free Chat

Chemical Treatment Requirements for Condensate Systems

Jul 10, 2017 · Corrosion damage in steam-condensing equipment and systems that collect, return and store condensate for reuse as boiler feedwater is a continuing problem at industrial plants, government installations, institutions, hotel, office and commercial buildings. Power engineers long have recognized that steam condensate is corrosive to iron and steel piping systems, and will attack many non-ferrous

Free Chat

Kettle Reboiler - an overview | ScienceDirect Topics

A kettle reboiler (Figure 10.1) consists of a horizontally mounted TEMA K-shell and a tube bundle comprised of either U-tubes or straight tubes (regular or finned) with a pull-through (type T) floating head.The tube bundle is unbaffled, so support plates are provided for tube support. Liquid is fed by gravity from the column sump and enters at the bottom of the shell through one or more nozzles.

Free Chat

How NOT to Design a Steam System - The C&S Companies

Dec 03, 2019 · A Weil Mclain SGO-8 gas fired steam boilerA Blast FromThe Past with super drop header. Even with this massive drop header and outstanding near boiler pipi

Free Chat

Drop header or not — Heating Help: The Wall

Jun 13, 2011 · They are a very good thing for a steam boiler, especially if the existing supply/feed is close to the recommended height above the water line in the boiler. Your supplies off the top of the boiler can go up much higher to the ceiling and back down to the header which has the equalizer and feed the system off the header. Keeps the steam drier.

Free Chat

Drop header or not — Heating Help: The Wall

Boiler Headers, Manifold Headers, Boiler Speed Headers

Free Chat

The subtlety of steam | PM Engineer

Aug 05, 2021 · The larger the header is, the lower the steam velocity will be, and that's good for everyone involved. The steam will leave the boiler very quickly; that's a given these days. A larger-than-required header will slow it down and give the carryover water a chance to drop back into the boiler rather than up into the system piping. Use a drop

Free Chat